Objective: To examine the prevalence of hearing impairment in children with hypothyroidism, and to characterize clinical and subclinical hearing loss by examining cochlear function, auditory brainstem pathways, and integration of the auditory sy[...]Article
Objective: The purpose of the present study was to investigate effective masking levels (EMLs) for bone conduction (BC) auditory brainstem response (ABR) testing in infants and adults. Early hearing detection and intervention programs aim to lim[...]Article
DisponibilitéExemplaires (1)
Cote Support Localisation Section Disponibilité Ear and hearing. Vol.28, n° 1 (Février 2007) Périodique papier Ixelles Rez Consultation sur place uniquement
Exclu du prêtArticle
Objectif: Le but était de quantifier l'effet de l'implant expérimental de conduction osseuse transcutanée active (BCI) sur la libération spatiale du masquage (MRS) chez des sujets présentant une perte auditive conductrice et mixte bilatérale ou [...]Article
Objective: The objective is to evaluate the electro-acoustic performance of a new audiometric bone vibrator, the B81 from Radioear Corporation, USA. Comparison will be made with the widely used B71 which has well-known limitations at low frequen[...]DisponibilitéExemplaires (1)
Cote Support Localisation Section Disponibilité International journal of audiology IJA. Vol.54, n°1-12 (January-December 2015) Périodique papier Ixelles Rez Consultation sur place uniquement
Exclu du prêtArticle
« Le masquage a pour but dempêcher loreille non testée de répondre à la place de celle en train dêtre évaluée, autrement dit déviter une courbe fantôme. Pour ce, on envoie dans loreille non testée un bruit dont le niveau doit être ajusté à [...]DisponibilitéExemplaires (1)
Cote Support Localisation Section Disponibilité Cahiers de l'audition. Vol. 18, n°4 (Juillet/août 2005) Périodique papier Ixelles Rez Consultation sur place uniquement
Exclu du prêtArticle
Estimation of Minor Conductive Hearing Loss in Humans Using Distortion Product Otoacoustic Emissions
Objectives: Conductive hearing loss (CHL) systematically alters distortion product otoacoustic emission (DPOAE) levels through attenuation of both the primary tones and the evoked response by the middle ear, as well as through modification of th[...]Article
Nouveau système externe à conduction osseuse (CO), lADHEAR est une option de réhabilitation récente pour les surdités de transmission et les cophoses unilatérales. Le maintien de laudioprocesseur derrière loreille étant assuré par un composan[...]Article
Objectif: déterminer si les microphones directionnels améliorent la capacité cognitive des adultes qui entendent généralement. Les objectifs de l'étude sont d'évaluer les différences dans (1) la reconnaissance vocale et (2) la mémoire de travail[...]Article
Design: This is a prospective, single-center, comparative, single-blinded study where the listeners served as their own control. Twenty-four experienced bone-anchored users with a bilateral conductive or mixed hearing loss participated in the st[...]Article
Lobjectif de la présente étude était dexaminer lutilité fonctionnelle de mesures généralement incluses dans la batterie de tests utilisée en audiologie, soit le seuil de réception de la parole, la conduction osseuse et les scores de reconnais[...]Article
Tadashi Nishimura ; Hiroshi Hosoi ; Tomoko Sugiuchi ; Nozomu Matsumoto ; Takanori Nishiyama ; Takano Kenichi ; Satofumi Sugimoto ; Hiroaki Yazama ; Takeshi Sato ; Masahiro Komori |Background Innovated hearing aids (HAs), termed cartilage conduction hearing aids (CC-HAs), show good performance in patients with closed ears and continuous otorrhea. However, factors other than the ear condition that influence the purchase ra[...]DisponibilitéExemplaires (1)
Cote Support Localisation Section Disponibilité Journal of the American Academy of Audiology. Vol.33, n°1 (January 2022) Périodique papier Ixelles Rez Consultation sur place uniquement
Exclu du prêtArticle
Objective Evidence-based protocols for fitting air conduction hearing aids to children offers a vital resource for audiologists. Fitting protocols for providing BCHDs to children are not well-developed, leaving gaps in clinical practice. This w[...]Article
Jennifer L. Spiegel ; Bernhard G. Weiss ; Mattis Bertlich ; Ivelina Stoycheva ; Martin Canis ; Friedrich Ihler |Objective In patients with conductive (CHL) or mixed hearing loss (MHL), hearing rehabilitation with an implantable hearing system, active middle ear implant (AMEI) or a semi-implantable bone-conduction device (SIBCD), is an option when convent[...]Article
Background: Bilateral hearing is important for learning, development, and function in complex everyday environments. Children with conductive and mixed hearing loss (HL) have been treated for years with percutaneous coupling through an abutment[...]DisponibilitéExemplaires (1)
Cote Support Localisation Section Disponibilité Journal of the American Academy of Audiology (JAAA). Vol.27, n°10 (November 2016) Périodique papier Ixelles Rez Consultation sur place uniquement
Exclu du prêtArticle
Objective To investigate the influence of maximum power output of bone conduction hearing devices on speech recognition in quiet and in noise in experienced users of bone conduction hearing devices. Design Prospective, randomised cross-over i[...]Article
Objectif: Cette étude explore l'influence de la position de stimulation sur la sensibilité auditive de la conduction osseuse (BC) avec un transducteur BC attaché à l'aide d'un bandeau. Conception: ( 1) Le mouvement du promontoire cochléaire a ét[...]DisponibilitéExemplaires (1)
Cote Support Localisation Section Disponibilité International journal of audiology IJA. Vol. 55, n°1-12 (January-December 2016) Périodique papier Ixelles Rez Consultation sur place uniquement
Exclu du prêtArticle
Background: Hearing can be induced not only by airborne sounds (air conduction [AC]) and by the induction of skull vibrations by a bone vibrator (osseous bone conduction [BC]), but also by inducing vibrations of the soft tissues of the head, [...]DisponibilitéExemplaires (1)
Cote Support Localisation Section Disponibilité Journal of the American Academy of Audiology (JAAA). Vol.28, n°2 (February 2017) Périodique papier Ixelles Rez Consultation sur place uniquement
Exclu du prêtArticle
Objectives: The appearance of low-frequency air-bone gaps (LFABGs) in Meniere's disease (MD) is a recognized but relatively unexplored phenomenon. Two theories have been proposed to explain their etiology: increased perilymphatic pressure result[...]Article
Yves Lasry, Auteur |Dans le domaine de l'audiologie, la mesure audiométrique en conduction osseuse constitue un élément crucial, représentant à la fois un pilier de lévaluation auditive et un défi technique persistant pour les professionnels du secteur. Limportan[...]DisponibilitéExemplaires (1)
Cote Support Localisation Section Disponibilité Cahiers de l'audition. Vol. 36, n°6 (Décembre 2023) Périodique papier Ixelles Rez Consultation sur place uniquement
Exclu du prêtArticle
Objectives: To study the effectivity of a transformed NAL non-linear version 2 (NAL-NL2) gain prescription for percutaneous bone conduction devices (BCDs) and to investigate how to take into account output constraints for the lower frequencies. [...]Article
The feasibility and repeatability of neonate auditory brainstem responses (ABRs) with a controlled hand-held applied force gauge for bone-conducted stimulus delivery was examined. Design: A repeated measures testretest design was employed. Stud[...]DisponibilitéExemplaires (1)
Cote Support Localisation Section Disponibilité International journal of audiology IJA. Vol. 57, n°1-12 (January-December 2018) Périodique papier Ixelles Rez Consultation sur place uniquement
Exclu du prêtArticle
Ann-Charlotte Persson, Auteur ; Bo Håkansson, Auteur ; Moksha Caveramma Mechanda, Auteur ; William Bill Hodgetts, Auteur ; Karl-Johan Fredén Jansson, Auteur ; Mans Eeg-Olofsson, Auteur ; Sabine Reinfeldt, Auteur |Objective Objective measurement of audibility (verification) using bone conduction devices (BCDs) has long remained an elusive problem for BCDs. For air conduction hearing aids there are well-defined and often used objective methods, and the ai[...]Article
Objectives: The maximum output provided by a bone conduction (BC) device is one of the main factors that determines the success when treating patients with conductive or mixed hearing loss. Different approaches such as sound pressure measurement[...]Article
Sophie M. McFarland ; Rachael Powell ; Kevin Green ; Rachel Andrew ; Kathryn Coppack ; Penny R. Hill-Feltham ; Alison Wearden |bjectives: Bone conduction hearing implants (BCHIs) are an effective option to rehabilitate hearing for people who cannot use conventional, air conduction hearing aids. However, the uptake of such devices in the United Kingdom is lower than migh[...]